To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 165 of 5219

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Allow modification of parent attribute|child attribute as a column name

When creating a table in PI Vision, I am unable to remove the display only the child attribute (as opposed to parent attribute|child attribute) in the name column. It would save space and allow for a cleaner display if I did not have to show the p...
Guest over 2 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Be able to choose custom format for plots in displays directly in the PI Processbook to PI Vision Migration Utility

When migrating displays, plots display the tag names by default. Setting the "Legend" option under "Custom Format" solves it, but you need to do it manually, one by one. It would be very useful to be able to choose plots' formatting during the mig...
Guest over 2 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Being able to hide the Asset Selection and Calculations Icon in the side toolbar

We have a particular GMP PIVision installation where users should be able to only open validated displays, without having the possibility to add attributes/tags to the display. This is a requirement to be able to use PIVision in a GMP Environment.
WimBorms over 2 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Reverse axis of XY plot

I'd like AVEVA to add a function to reverse axis of XY plot on PI Vision. It is helpful when we show the profile of a distillation column temperature. We'd like to set Stage 1 on the top.
AGC_Koba over 2 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Save more symbol attributes to default

At present it is possible to save a limited range of symbol style settings to a default setting such that new users are conforming to an organisational visualisation standard. However this is not the full range of attributes that can be altered wh...
Guest about 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 2 No status

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea about 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

UniInt Interface to support Kerberos when connecting to network drive for failover file

My ops team tells me that our UniInt-based interfaces (e.g. PItoPI, PerfMon, OPC DA) authenticate to network drives (when reading/writing failover files) using NTLM. I'm told Kerberos is much more secure than NTLM and they would like to see that b...
taterhead247 over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Fix Bug for OPCInt_ReadWrite_2.7.2.20_.exe with Plug-in

I have high-frequency data need to collect,when i use OPC DA Plug-in TimeArray of OPCInt_ReadWrite_2.7.2.20_.exe ,it does not work.then i uninstall the opc interface 2.7.2.20 and install OPC DA 2.7.1.41,The Plug-in TimeArray work well.
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 2 Tell us more