Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 94 of 5194

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 Declined

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest about 1 year ago in PI Interfaces / PI Interface for OPC DA 1 No status

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

PI Connector for Siemens SIMATIC PCS7 Alarm and Conditions backfilling support

In case of an interruption, the PI Connector has the current capability of backfilling any tag data from the source OpenPCS 7 system. Condition data leading to PI Event Frame creation from the connector should also support similar backfilling cap...
Archie Gale over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Option to set Client_ID parameters in MQTT SparkPlug Connector.

We need to have an option to set the Client ID parameter. We need an option to set the starting set of the characters of the parameter to have the possibility to use the fixed text "cva::" before a random number. Thanks
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

Allow OPC DA  Output Tags to capture OOO events

Currently there is no way to send corrected values to the OPC DA Server since they are triggered by snapshot. It would be useful if there was a way to alter the values that get sent in case there are substituted/replaced values.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

Automatic restart of the OPC interface whenever OPC server is restarted

whenever the OPC server undergoes any restarts or configuration changes, the OPC interface will delete all old connections, groups, etc. and it will establish a new connection to the OPC server, loading all ItemID's etc (as if it is an automatic r...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

PI Connector for HART-IP / Support SECURE data transfer

I work with an global oil and gas company who is interested in collecting data using the PI Connector for HART-IP but their IT requires them to utilize SECURE data transfer. The current connector only utilizes STANDARD data transfer. The lack ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Data Collection Manager (DCM) High Availability (HA)

I would like to have failover or high availability for the the PI Data Collection Manager (DCM)
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status