To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes: PI Interface for OPC DA

Showing 39 of 4777

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco about 1 year ago in PI Interfaces / PI Interface for OPC DA 1 No Status

Parameter for restarting the interface if no connection to the OPC server can be established after a defined period of time

We use the Phoenix Contact Firewall with the OPC Inspector. When the OPC server restarts or breaks the connection for a few seconds, the firewall blocks all ports except port 135. After initial connection through this port, new firewall rules are ...
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Se...
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,00...
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Any Patches/Updates needed to be ready for Microsoft's DCOM hardening in 2023?

By March 2023 Microsoft will enforce a patch that upgrades DCOM security. Some applications that use DCOM (such as the PI OPC interface) will require some updates to continue to work. Are there any updates that I need to apply on any of the PI com...
James_Podobea over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No Status

UniInt Interface to support Kerberos when connecting to network drive for failover file

My ops team tells me that our UniInt-based interfaces (e.g. PItoPI, PerfMon, OPC DA) authenticate to network drives (when reading/writing failover files) using NTLM. I'm told Kerberos is much more secure than NTLM and they would like to see that b...
taterhead247 over 1 year ago in PI Interfaces / PI Interface for OPC DA 0 No Status

Fix Bug for OPCInt_ReadWrite_2.7.2.20_.exe with Plug-in

I have high-frequency data need to collect,when i use OPC DA Plug-in TimeArray of OPCInt_ReadWrite_2.7.2.20_.exe ,it does not work.then i uninstall the opc interface 2.7.2.20 and install OPC DA 2.7.1.41,The Plug-in TimeArray work well.
Guest 1 day ago in PI Interfaces / PI Interface for OPC DA 1 Tell us more

Device status tags do not show OPC DA server Invalid client handle errors

When OPC DA interface receives an "Server returned Invalid Client Handle" error, device status tags do not show that error and therefore potential situations where data is not being received by the interface are missed I would be good that device ...
asanzacedo 3 months ago in PI Interfaces / PI Interface for OPC DA 0 No Status

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest 11 months ago in PI Interfaces / PI Interface for OPC DA 1 Planned

PI interface for OPC DAの配列型タグ対応

PI interface for OPC DAを配列タグ対応にしてほしい。東芝製DCSのデジタルデータの場合、状態を配列型で存在している(例:種別「PB8」、ITEM「LS1」の場合8ビット。種別「PB4」、ITEM「SS1」の場合4ビット)。この値を取得する際、1ビットずつ取得した後にAF演算で1つの値に計算している。対象全タグに対してこの処理を行うことは大変なので、interfaceのところで一度に全ビット取得し、1つの値として取り扱いたい。