Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 162 of 5259

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Create ArcGIS Feature Services and Layers with More Descriptive Names

Update the naming convention used to create ArcGIS feature services and layers to use names that more accurately reflect the services and layers stored on the Integrator side. Customer Issue: The current convention is to use numbers instead of the...
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 Declined

Be able to Write data to PI from Integrator Hosted Time Enabled Feature Services

Native ArcGIS Feature Services allow for features to be updated by performing a POST to the REST endpoint to "Apply Updates".  It would be good to be able to record new values to the PI Data Archive by "Applying Edits" to the features / Eleme...
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 Declined

Support Kerberos Authentication to the PI Integrator

The PI Integrator for Esri ArcGIS does not support Kerberos authentication to the Integrator. By adding support of Kerberos Authentication to the integrator means that when providing access to time enabled feature layers from external networks, t...
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 No status

Configuration improvements

Post configuration (for this installation we're only using manually configured services/layers), you must walk through the wizard again to see how the data store / service / layer might be defined in GeoEvent Server. For support in these condition...
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 No status

Allow the AF attribute description to used in the popup display instead of the AF attribute name

Pop-up display shows AF attribute named 'Level1' but instead I would like the map popup to use the AF attribute Description value for the field example "SiteName-Street-Weir Level' rather the AF attribute name 'Level1'. This is more descriptive an...
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...