To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 78 of 5194

Further development of OMF

In OMF unfortunately more complex use cases are not possible Integration of Script functionally for generated elements from OMF are needed. Please insert an possibility or allow an other development method to use all AF functionality in case of ge...
photi24 over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

GUI interface for connector configuration

PI-Connector-for-GE-e-terrahabitat-1.1.1.42 Suggest migrating the product to generation 2 of the PI Connector, which has a graphical interface for editing and configuring Point parameters to be created in the Data Archive. A graphical interface is...
Guest 9 months ago in PI Connectors / Other specific PI Connector 0 No status

Return row number from PI SQL Client calls

It would be useful to be able to access a specific row from a PI SQL Client call. For example if I query muiltiple attributes indicating some KPI ordered from highest to lowest returning 1000 rows, I might want to show only the top 10. The TOP fun...
Simon J. Dyson over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Allow the SDK connection priority for the RTQP Engine to be configurable

The RTQP Engine is currently only able to connect to the Primary Data Archive to retrieve data, regardless of the SDK Priority settings. The “PreferPrimary” connection priority is hardcoded into the RTQP engine and cannot be modified. For users wh...
Derek Wong over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 2 No status

Adjust GE e-terraHabitat Connector to support e-terraPipeline systems

The Pi Connector for GE e-terraHabitat systems was apparently only written to support GE's Electrical SCADA systems (EMS/DMS) that are based on e-terraHabitat. They also have Oil & Gas Pipeline SCADA systems, also based on e-terraHabitat, know...
KPRoth over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Add support for nested SELECT statements in PI SQL (RTQP)

The current version of PI DAS (RTQP Engine) does not support nested SELECT statements. This is a rather dire oversight, given that the older PI OLEDB Enterprise query engine does support nested SELECT statements. A very useful application of nes...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status

Enable child Event Frames for Alarms and Conditions from PI Connector for Siemens Simatic PCS 7

Would like to see states of alarms captured as child Event Frames of the parent alarm Event Frame that is currently created. Today this data is only captured in tags.
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

Collect units of measure and description from Siemens Simatic PCS 7

Support collecting units and description from the Siemens Simatic PCS 7 system and writing them to the AF attribute and the PI Point attributes.
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 Declined

Provide a PI SQL Commander Lite Standalone Download

Currently, PI SQL Commander Lite is bundled with PI SQL Client, PI OLEDB Enterprise, and PI ODBC Driver. It is a very useful tool for PI OLEDB Provider, which does not bundle it. To use it, another provider needs to be installed to obtain PI SQL...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 2 No status

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status