To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 238 of 5257

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 5 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi 11 months ago in AVEVA™ Adapters / General 0 No status

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 3 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Update PI Web API with AF SDK supporting .NET 10

With the announcement of a new .NET 8 AF SDK at AVEVA World 2023 coming sometime in 2024, we would like to see a new version of the PI Web API that adopts this new version.
Alec Lord about 2 years ago in AVEVA™ PI System Access (PSA) / PI Web API 4 Planned

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 3 years ago in AVEVA™ Adapters / General 7 Future consideration

Implement a checkpoint system for index crawls

When the crawler fails on an incremental crawl, the index search must perform a complete rebuild of the index. It would be beneficial for there to be a way to revert to a previous built index just prior to the failed incremental crawl so that the ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 2 Declined

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status