Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Multiple PI to CONNECT agents for one PI Data Archive

Aside from our main AF Server setup used for numerous use cases like energy, OEE, etc, we have created a second environment of AF Server / AF Analysis / SQL Server to isolate the monitoring of a critical process. We are still making use of a singl...
Christian Leroux about 3 years ago in PI to CONNECT / General 0 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Tools to assist in configuring and testing Kerberos delegation

As a PI Administrator, I need assistance configuring and testing Kerberos delegation, so that I can access the full functionality of the products without exposing my system to potential threats.
Guest almost 4 years ago in AVEVA™ PI System Access (PSA) / PI Web API 0 Declined

PI Web API OMF send to multiple PI Systems

I would like to be able to setup the PI Web API OMF endpoint to point to multiple PI Systems, so that way it is easy to send from this single instance to different production systems or to our development and production environments concurrently
Guest almost 4 years ago in AVEVA™ PI System Access (PSA) / PI Web API 1 Declined

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins over 2 years ago in AVEVA™ Adapters / General 2 Already exists

PI to CONNECT should have a verification tool to make sure there are no gaps in the data

When using PI to CONNECT there might be errors in the transfer due to disconnections or other network issues. Ideally PI to CONNECT would have a tool to verify if the data was properly transferred by checking the data.
Fabio Dani about 1 year ago in PI to CONNECT / General 0 No status

Support string builder attributes

String builder attributes are incredibly useful for including helpful Asset Framework metadata and context. They are widely used throughout AF deployments, and this data is very helpful for downstream analysis and interpretation of AF data. The PI...
Daniel Lopez almost 2 years ago in PI to CONNECT / General 3 No status