Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Other specific PI Connector

Showing 50

Enable setting tag attributes in MQTT Connector

The MQTT Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

Further development of OMF

In OMF unfortunately more complex use cases are not possible Integration of Script functionally for generated elements from OMF are needed. Please insert an possibility or allow an other development method to use all AF functionality in case of ge...
photi24 over 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Adjust GE e-terraHabitat Connector to support e-terraPipeline systems

The Pi Connector for GE e-terraHabitat systems was apparently only written to support GE's Electrical SCADA systems (EMS/DMS) that are based on e-terraHabitat. They also have Oil & Gas Pipeline SCADA systems, also based on e-terraHabitat, know...
KPRoth over 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable child Event Frames for Alarms and Conditions from PI Connector for Siemens Simatic PCS 7

Would like to see states of alarms captured as child Event Frames of the parent alarm Event Frame that is currently created. Today this data is only captured in tags.
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

Collect units of measure and description from Siemens Simatic PCS 7

Support collecting units and description from the Siemens Simatic PCS 7 system and writing them to the AF attribute and the PI Point attributes.
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 Declined

Allow rename of tags for IEC-60870-104 connector

The connector should allow sending the data to a custom tag name. The combination of ASDU and IOA are not useful to end users without the signal list. There should also be an option to automatically combine the quality flags with the value e.g. i...
sahilp over 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 0 Declined

PI Connector for Siemens SIMATIC PCS7 Alarm and Conditions backfilling support

In case of an interruption, the PI Connector has the current capability of backfilling any tag data from the source OpenPCS 7 system. Condition data leading to PI Event Frame creation from the connector should also support similar backfilling cap...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Option to set Client_ID parameters in MQTT SparkPlug Connector.

We need to have an option to set the Client ID parameter. We need an option to set the starting set of the characters of the parameter to have the possibility to use the fixed text "cva::" before a random number. Thanks
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status