Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 187 of 5194

Notifications for events in the past

Currently notifications are not triggered (send) by events that are more than 72 hours in the past. For me it is necessary to get notifications from events in the (endless) past. Ideally I would like to configure for each notification separately t...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 8 No status

Ability to send a notification without being triggered by an event frame

As a notification user I want to receive a report on daily or weekly basis but I don’t want to store any associated data about it like the event frame information or the notification history since I use event frames for other purposes and I don’t ...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 3 No status

Enable headers for SOAP Web Service Notifications

The feature added in 2017 R2 was for authentication of the SOAP payload, not for managing headers within the payload.  PI remains unusable as a secure source of data for Maximo without it because you can't configure a MAXAUTH header. There's...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 4 No status

Enable setting tag attributes in UFL Connector

UFL Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 3 No status

Attachment in a Notifications from a file path

As an AF administrator, I  would like to send in an attachment of a Notification files that are specified by file path in AF attributes. I currently do this by specifying the value at start time of an AF attribute that contains the changing f...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 No status

Ability to clear and not send notifications on Notification service startup.

We've had issue with Notifications spamming users with events should a PI collective member stop getting data. At times, we need to disable the notification service until we can resolve the issue. After the issue is resolved, we need to start th...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 10 No status

Feature to turn off auto creation of PI Tags in PI Connector for UFL

Ability to turn off auto creation of PI tags - When data is sent via REST to a PI Connector for UFL service ,currently it looks for a PI Tag in the PI Server and if the PI Tag does not exist it creates a new PI Tag. It would be good if we could tu...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 7 Declined

Feature to enable notification rules automatically

When deactivating an alarm, the notification rule is disabled. There should be a way to set a notification rule to be enabled in a certain number of days. For example, if I disable the notification rule, I want to set it to be reenabled automatica...
Alexa Derago 3 months ago in AVEVA™ PI Server / Notifications 1 No status

Enable or Disable single DataSource

When a datasource is actually offline and we don't want the UFL connector to keep trying uploading or connecting to it and pollute the message log . The best option would be having the stop/start enable/disable and restart options for each dataso...
Andy over 3 years ago in PI Connectors / PI Connector for UFL 3 Declined

UFL Timezone Conversion

Supported timestamps are currently limited to Local or UTC timezones. Data sources may not be configurable to provide timestamps in supported formats. There currently exists no robust or simple way of converting between timezones using the UFL...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 5 Declined