Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 178 of 5259

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 3 years ago in AVEVA™ Adapters 3 Future consideration

Configurable input REST data queue file size for PI Connector for UFL

We're working with a large AMI customer, using the PI Connector for UFL as a REST server endpoint to receive meter data. However, during large interrogations, the amount of messages received can be faster than UFL can process, leading to overflowi...
Kendell Jillson 4 months ago in PI Connectors / PI Connector for UFL 0 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins almost 2 years ago in AVEVA™ Adapters / General 2 Already exists

Make the UFL Connector logic development/testing/debugging process less tedious

Deploying a UFL Connector solution requires a LOT of edits of the INI file as part of the development/testing/debugging process. After each INI file change and file save, the required procedure is as follows: 1. Click on the Data Source List link...
Mic Paluszak over 3 years ago in PI Connectors / PI Connector for UFL 0 Declined

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock almost 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee over 2 years ago in AVEVA™ Adapters / General 2 No status

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
sahilp 6 months ago in AVEVA™ Adapters / General 0 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 1 No status