To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 659 of 5259

OPC UA bi directional communication

like the PI Interface OPC DA, it would be good to have the possibility to read and write value back to the source system.
Pascal_13 about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Edit PI Vision symbols configuration in bulk

Possibility to edit PI Vision symbols configuration in bulk (text color, size, format, labels, images, ...) with PI Vision Display Utility.
Eduardo Miller over 3 years ago in AVEVA™ PI Vision™ / Authoring Displays 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server. There are documented known issues related to the slow ICU loading...
Guest about 1 year ago in PI Interfaces / Other Interfaces 0 No status

Support VHS point History recovery for PI Connector for Cygnet

VHS points in Cygnet contain historical data. On startup, disconnection and at will, the connector should should attempt to recover history.
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status