To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 659 of 5258

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee about 2 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Pi adapter OPCua able to rename pi-tags

As per title
Rob Chew 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Tell us more

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 16 Planned

Output tags on connectors

Sometimes we need to send data back to our sources. Connectors should support output tags
Alan Izar over 3 years ago in PI Connectors / General 8 Declined

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Transformations and scaling

Add the ability to configure PI points so that the PI Connector for OPC UA performs transformations and scaling on the values before being archived.
Jose Sanchez Colunga over 3 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

Ability for PI Connectors to create future data point

Add the ability for PI Connectors to create future data point. This is especially useful for the PI Connector for UFL. The current workaround is to manually create the point as a StoredValues=FutureData.
Gabriel Verreault over 3 years ago in PI Connectors / General 0 No status

PI Interface for Performance Monitor - Parameter to Ignore Device Status for Failover Pairs

When machines being monitored by the Performance Monitor Interface go offline, PerfMon Interfaces in failover pairs can thrash due to the health point device status for the machines not being resolved after a failover event. (The machine is still ...
Joshua Weishaar about 1 month ago in PI Interfaces / Other Interfaces 0 No status

Enable setting tag attributes in UFL Connector

UFL Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 3 No status

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...