Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 49 of 5194

REST API data source

e.g.: weather forecast, 3rd party
Guest about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for Apache Kafka

Create a PI Adapter that supports reading data from Apache Kafka. Please comment with any specific data, requirements, or use cases that this adapter would need to support!
Ellery Murdock over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp 11 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Improve the message for performing on demand History Recovery on datacollectionmode: "CurrentWithBackfill" and "CurrentOnly"

Running edgecmd to perform HR on demand on the datasource: datacollectionmode of Non HistoryOnly. will return the following error: Operation Failed: NotFound (404)Unexpected error: Unexpected character encountered while parsing value: 0. path '", ...
Ee Sheing Lee over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

scaling/scale data selection(s)

Simplify data management, setting scale at source
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Discovery file attributes setting

At the moment the file generated consists 5 columns - nodeId,selected,name,streamId,dataFilterId. Columns "name" and "dataFilterId" are always with value "NONE". There is no option to set the attributes to include in the file.
Ivan Lozanov over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status