Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 162 of 5264

Add the ability to multi-select and move display columns in Asset Filter Search, Explore Events, and Compare Events

Currently, only a single item can be selected and moved (or deleted) in the "Attributes to display" list in Asset Filter Search. An analagous behavior exists in the "Columns to display" list in Explore Events, and Compare Events. For each of these...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Task Pane 3 Declined

PI DataLink Time Filtered Function should be as accurate as the results given by an equivalent Analysis.

For example: Time Filtered in DataLink with: 'sinusoid>98' Start Time: Y End Time: T Should give the same result as: TimeGT('sinusoid','y','t',98)
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 Declined

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Populate child attribute in Asset filter Search - Attribute to display

Child attributes are populated in the Attribute value filters section of the Asset filter search but have to be entered manually in the Attributes to display section. Users not familiar with the AF syntax or AF hierarchy have trouble entering/find...
Marc-Olivier Baillargeon almost 3 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow users to choose to AND or OR each filter condition in

Allow users to choose to AND or OR each filter condition in the PI tag search. Currently all filter conditions are AND. Note: This was previously Enhancement 26991OSI8
Guest over 3 years ago in AVEVA™ PI DataLink™ / Search 1 Declined

Return the Values of Timestamp Data Items in Timestamp Format

The values of timestamp tags or AF attributes should be formatted as timestamp in Excel by default. Currently they are returned as integers, and then users have to manually convert them into timestamps.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Format 0 Declined