Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

112 VOTE

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 10 Future consideration

Fix awkward duplicate wording when deleting a data filter

When I tried to delete the default "DuplicateData" data filter, the attached error message appeared ("Are you sure you want to remove this array item array item?"), but it reads awkwardly because of the duplicated "array item". The 2nd "array item...
Kenneth Barber 15 days ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Include more details in Transfer Health Stream

The TransferStatus property of the Transfer Health Stream currently does not show warning messages generated during a transfer. It is limited to messages like "Stopped", "Started" or "Initializing". This makes it difficult for end users to detect ...
Derek Wong 3 months ago in PI to CONNECT / General 0 No status

AVEVA™ Adapter For Ping

I realize that there is already a PI Interface For Ping and a PI Connector For Ping, but that logic didn't stop other AVEVA Adapters from being created (e.g. AVEVA Adapter For BACnet). An AVEVA Adapter For Ping would allow us to continue to check ...
Kenneth Barber 18 days ago in AVEVA™ Adapters / New Connectivity 0 No status

It would be great to have an option to backfill/recalculate Event Frame analysis without sending notificaiton.

I know, that notifications are not sent for event frames older than 72 hours, but that 3 days is still too long. Usually we just want to recalculate  Event Frames to have a proper statistic about the past in reports. The notification is use...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 10 No status

Rename services to reflect the renaming of the product

AVEVA Adapters were previously called "PI Adapters", but the name of any AVEVA Adapter service begins with "PIAdapter". The PI To CONNECT Agent was previously called the "PI To Data Hub Agent", but the service name is still "PIToDataHubAgent". I'm...
Kenneth Barber 19 days ago in AVEVA™ Adapters / General 0 No status

PI Tag Mapping configuration in the background of PI OPC UA Adapter to use Point ID

The CSV / JSON file in the background will have the mapping between the OPC UA Server tag against its' respective PI Tag Name. In such case, if we need to change the tag name after sometime, then which results in multiple process like stop the Ada...
Navaneethakrishnan 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 8 In development

PI Notifications OAuth authentication option for SMTP server

Possibility to have the OAuth option for SMTP server authentication in PI Notifications.
Eduardo Miller over 1 year ago in AVEVA™ PI Server / Notifications 1 In development

Allow Copy & Paste of Notification Rules

I would like to be able to copy a notification rule in PI System Explorer from an existing element or template and paste it on another element or template. That way when I have similar notification rules, I can copy/paste and make only the changes...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 6 No status