To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Analytics & Calculations

Showing 333 of 5209

Add 'Stopped by user' status for analysis

As an AF administrator, I would like to understand the difference between an analysis that is stopped by an end user, or an analysis that has stopped but should likely be running. Currently when an analysis is stopped, we do not know if this is ex...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove requirement for shared volume for PI Analytics and PI Notifications high availibility

Our corporation has highly available PI in a number of sites. Our PI infrastructure is highly available except for Analytics and Notifications. The requirement for a shared volume for the failover cluster is not supported. We can support the failo...
Nathan Anderson 8 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Option to not have Value Retrieval Method and TagTot "fill in the gaps"

When taking a Total using Value Retrieval Method (configured in AF Attribute) or using TagTot (an AF Analytics function), PI will "fill in" gaps in the data. For instance, if you have a Float32 tag that is reading good for half of the day and then...
taterhead247 about 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

TagTot should make use of input UOM when no output UOM is defined

TagTot will automatically account for UOM that have the time dimension as something other than per day only when the input has an assigned UOM and the function has an output UOM defined. It would be friendlier if the output UOM was defaulted based...
Mike Horrocks 10 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Recover data from current time moving backwards

Recover data from the current time back rather than start of a data gap to now (current time). The most important thing is to get current data immediately.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined

Implement default calculations existing in EXCEL.

Implement all the default calculations existing in EXCEL. We need to calculate the IRR (internal rate of return) for every technology: Inside the PI Analysis is not already available the function to calculate the IRR (like for the vb.net, Excel, ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Easy output attribute mapping search in PSE

No description provided
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Better Error Handling and Reporting

On more than one occasion, have missed several days worth of calculations with no indication of a problem. There were errors in the log, however there is nothing monitoring this log. The analytics service was running, but not actually doing anythi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Event frames start trigger on trigger condition change

I would like to be able to define start trigger that fires a e new event frames only if the start condition changes. I mean: - Start trigger: 'Equip Status' = "ON" - End trigger: 'Equip rpm' >= 1000 I would like that the event start is triggere...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status