To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Support of EEC (Elliptic Curve Digital Signature Algorithm ) Certificates

Make the Connector, DCM and Relay support EEC (Elliptic Curve Digital Signature Algorithm) Certificates in future versions. Admin Certificates can be exchanged manually usinmg netsh, but the usage of RSA encrypted certificates is required here.
Julian Baur over 3 years ago in PI Connectors / General 0 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow user to choose a variable name when using "Assign to variable" feature

First of all, the "Assign to variable" feature in asset-analytics is amazing and helps a lot with refactoring previously created analyses, so kudos and thanks! What would be even more amazing is if I had the ability to select a variable name wen a...
Alassane Seck over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Analysis to use "BadVal"

We have many cases where data is showing up as "questionable" and thus cannot be used in an analysis even tho the value is still mostly good and can still be accurately used in a calculation. Being able to choose to use these "BadValues" would be ...
JACKSON DALY over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha over 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Add the feature to create writing tags via OPC UA

In the OPC DA adapter, we are able to write values if we create a PI Point with a specific Point Source (that is prepared to receive values) and if we configure the source tag properly. This kind of feature is not available in OPC UA, and it would...
Lucas Mazutti over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

PI FrequencyGT function and PI FrequencyLT need to be added in AF analysis.

Please add PI FrequencyGT and PI FrequencyLT functions in AF analysis, like PI TimeGT and PI TimeLT, which find the frequency (number of times) within a range when an attribute value is greater or less than a given value.
MOUFID over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status