To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 730 of 5194

Permissions to discover and create tags only

Create the ability to give users permissions to discover and create tags only in PI Data Collection Manager. We were able to give users the ability to only create tags when using OPC DA interfaces, but we can no longer do this with PI DCM. This se...
David Sugden about 1 year ago in PI Connectors / PI Connector for OPC UA 0 No status

Performance Tab "Jump to" Option

When trying to troubleshoot analyses and templates that may be causing poor performance on the "Management\Performance" tab, it can be tedious to locate the selected element to start determining why it's building in error count or taking a long ti...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Quadratic Regression

Add a quadratic regression function similar to "LinRegr". This would be helpful for trending relationships that are not linear, such as flow vs. pressure.
Guest about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Analysis timerule option: Add a possibility to make the timerule conservative. Emit calculation events only if the snapshot time of all inputs are more recent than the planned calculation time.

Now the TimeRules Natural and Periodic emit events to the Data PIPE in case NATURAL: an event is received by one of the selected inputs case PERIOD: when a certain timespan elapse.Both method doesn't take into account that some input of the analys...
Marco Blokdijk about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide a tool (in PSE?) to assist management of analytics scheduling offsets

We recommend customers use offsets to distribute scheduled calculations across time but there is not a good way manage this.Propose some utility to list a group of all scheduled analyses by same period, users supply X number of offsets and then th...
Brian Deslatte about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI Connector for Wonderware to be able to detect dll files in other drives other than C drive

Had a customer that just installed PI Connector for wonderware of current version (v1.6.9.14) and his connector is unable to start. Upon discussion after troubleshooting, it was noted that the directory where dll files can be located on customer's...
Chaur Ann Poh about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Need EtherNet/IP connector to be able to read and write.

Need EtherNet/IP connector to be able to read and write. Currently EtherNet/IP connector is read only.
Francis2 over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Wonderware Historian Connector - Allow Custom Tag Naming

The Wonderware/AVEVA Historian has some different illegal characters than PI tags and there are also cases where a single tag prefix isn't sufficient (e.g. when storing data from multiple buildings in the WW Historian). The Connector should have t...
Sublette-Sanofi over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

support linked tables for system connector

some of our data reside outside the PI System (e.g. in a LIMS System). to commuicate this kind of data to a global PI System, also linked tables and it values need to be sent to the global PI System.
FranzK over 3 years ago in PI Connectors / PI System Connector 0 Declined