Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow Analysis to use "BadVal"

We have many cases where data is showing up as "questionable" and thus cannot be used in an analysis even tho the value is still mostly good and can still be accurately used in a calculation. Being able to choose to use these "BadValues" would be ...
JACKSON DALY about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow PI Web API Admin Utility to run silently

We use the command following command to run the PI Web API Admin Utility silently in order to automate SSL certificate updates: OSIsoft.REST.Admin.exe --f=C:\temp\InstallationConfig.json --suppressUI=0 --verbose If the admin utility crashes, this ...
Guest over 2 years ago in Developer Resources / General 1 No status

Fix for KI: EventFrame Extended property not removed after EF is closed

The first EFs created by the PI Analysis Service after a restart can have the Extended Property StatusInAnalysisService stuck in Reconciling even after the event frame has been closed. There is a workaround to fix the issue when it occurs (see Eve...
Miranda Hill over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Analyzes are automatically switched off by the PI Analysis Service

In the case, that the PI AF Analysis Service is overloaded, there should be the possibility that faulty analyzes are automatically switched off by the PI Analysis Service. This ensures that all other analyzes functioning correctly. The failed anal...
Marcel Rieß over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI FrequencyGT function and PI FrequencyLT need to be added in AF analysis.

Please add PI FrequencyGT and PI FrequencyLT functions in AF analysis, like PI TimeGT and PI TimeLT, which find the frequency (number of times) within a range when an attribute value is greater or less than a given value.
MOUFID about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI System Explorer > Preview Results: trends should allow for Inputs/Outputs to be selected/deselected

It can be difficult to clearly see the input/output trends in the prevew when trying to perform debugging. Specifically it would be useful to isolate the mapped output(s) to see if the analytic it producing the expected results. The table is usefu...
Mike Horrocks over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Ability to disable file renaming for AVEVA Adapter for Structured Data Files or PI UFL products.

The pharma industry has to abide to GMP regulations, in this scenario, the original files should not be modified or renamed. It would be good to have an end to end solution with PI System products instead of making copies of the original file.
Alex Santos over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks over 2 years ago in AVEVA™ Adapters / General 1 No status

API Console request-timeout and paging support

Provide option to modify request-timeout setting and optionally return multiple pages to aid in querying datasets and learning about the API
Guest over 3 years ago in Developer Resources / CONNECT data services Developer Tools 0 No status

Expose Analysis Service Evaluation Queue Count

For complex systems it is important to monitor the PI Analysis Service closely. The existing performance counters are helpful but we would really like the EvaluationQueueCount to be available as well. This would help determine if the EvaluationsTo...
Steve Boyko over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status