To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 142 of 5192

Make the Agent recrawl the AF/PI Point database from scratch

Make the agent recrawl the AF/PIPoint database from scratch every now and again and update its cache if required. I think this is what PI Vision does, so it doesn't have these limitations.
Guest 4 months ago in PI to CONNECT / General 0 No status

Allow selection of output timestamp for values written by the outputs at close feature in Event Frames

It would be nice to have the option to select either starttime or endtime of the eventframe as the timestamp for the value that will be written a PI tag using the Outputs at close feature in Event Frames. Currently, it will only write the value wi...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 5 No status

Allow Multiple Data Archives per PI to CONNECT Agent

Allowing data transfer for tags from multiple PI Data Archives with one agent will help to cut down on the number of agent services, and therefore machines, that need to be involved to send data from PI to CONNECT.
Guest over 3 years ago in PI to CONNECT 0 In development

Custom Severity Levels for Event Frames (EF) Triggers

Enable the ability for end-user to manage custom severity levels for event frames, to allow for better communications across response teams and business unit functions. Exposing EF severity levels within a PI Notifications messages is very helpfu...
jtepfer@ebay.com over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Monitor PI to CONNECT connection

Sometimes, the PI to CONNECT agent seems to have some interruption in replicating data from a PI Data Archive into CONNECT data services. It would be beneficial to have some more monitoring options (in addition to what is available through the CON...
Guest over 3 years ago in PI to CONNECT 1 In development

Event Frame (EF) Linking

Ability to link Event Frames coming in from different sources (batch & mes interfaces, EFgen, PI Analytics, custom, etc.) together based on rules and monitoring an EF attribute SO THAT it's easier to associate time frame context and data that ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Aggregate event frames to a time series

As an user, I want to be able to treat event frame like time series data, such as number of active event frames, sum of an attribute, so that I can continuously monitor the evolution of event frames over time.
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Stop EF after given time

Als a PI admin I want to have the option to stop/end a EF after a given time. This helps to trigger and track onetime events as for example taking a reactor sample.
meierke1 over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 3 No status

Allow selective AF Database indexing

The PI to CONNECT agent will index the whole AF server. On big ones, this is tedious (one took more than 12 hours) - would prefer to have the ability to choose either on the agent or from CONNECT which AF databases to index.
Guest over 2 years ago in PI to CONNECT / General 1 No status

Acknowledge of Event Frames requires Reason Code / Comment / Electronic Signature

It should be possible to configure event frames to be acknowledgeable only if a comment/reason code is entered before. we have this requirement sometimes in life science industry, but i can imagine it might be also usefull in other industries (e.g...