To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Provide option to re-use or not re-use OIDC access tokens when connecting to multiple AF systems using PI System Explorer

At the moment, PI System Explorer defaults to re-using OIDC access tokens when connecting between AF systems. For customer systems where there are multiple independent AIM servers for different AF systems (potentially because of different countrie...
Tze-Wei Lim 6 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Ability to use substitution parameters in attribute template names

Would like ability to use substitution parameters in attribute template names.  Using PI-SNMP for Linux file partition data. We need to know the storage index# in AF since they vary server to server.  Want to provide users doing searches...
Guest almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest almost 4 years ago in AVEVA™ Adapters 4 Future consideration

PI Adapter for AspenTech IP21

We have customers who are using AspenTech IP 21 and would like to have data replicated in both PI DataArchive and OCS in the future. Since the PI Interface is a bit outdated, a new PI Adapter would make perfect sense (since there is already a PI C...
Guest almost 4 years ago in AVEVA™ Adapters / New Connectivity 4 Tell us more

Add ability to uncheck or remove attributes from existing transfer

Transfers are initially added by searching and then selecting elements then attributes to add. When we want to edit the transfer, we are only able to remove entire elements, not by attributes. This became an issue when we later found that we had a...
Guest over 1 year ago in PI to CONNECT / General 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Ability to change the timezone used in PI System Explorer with a feature similar to what is found in PI DataLink or PI SMT 2017.

As an end user, I would like to be able to change the timezone referenced in PI System Exporer from client timezone to server timezone. Something similar to the "PI Data Archive Time Zone"  setting found in PI DataLink would be helpful.
Guest almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 8 No status

Add filters support to AF Summary calculations

PI-DataLink allows for filtering of aggregate calculations, for example to get the average inlet temperature of a compressor when the turbine speed is > 1000 RPM. This is not possible with AF. The KB01120 article does not work and is very mess...
Simon J. Dyson almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 6 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 11 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 2 No status