To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Use EDS to download OCS and PI data for use as a local data cache for Data Science in tools like R-Studio and Jupyter Notebook

As a data scientist, I would like to set up types, streams, and query data from OCS to use locally on my desktop in data science languages (e.g. R, Python) and tools I use (R-Studio, Jupyter Notebook) so that I can rapidly try different numerical ...
Guest about 4 years ago in Edge Data Store / Analytics & Calculations 1 Tell us more

EDS: security/authentication mechanism

Customer wants to deploy EDS at machine level to collect data from PLCs which are directly connected to the machine which would imply a proper security / authentication mechanism for EDS
Guest about 4 years ago in Edge Data Store / General 1 Tell us more

Average calculation not working through Pi Vision Calculation editor

Time-based average (eg. 15min average) calculation not working through Pi Vision Calculation editor. Presently while using Avg('tag'), the result is only the instantaneous value at the end of 15 minutes, and not the average over 15 minutes.
AK about 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 Already exists

Add a new diagnostic: the IO rate in bytes or megabytes

The current IO rate diagnostic is helpful, but it only shows events per second. For sites who need to manage their bandwidth and make decisions about how much to buy and support from remote sites, it's very important to be able to monitor exactly ...
Daniel Lopez about 2 years ago in Edge Data Store / Egress 0 No status

Add a text-based event point to trend traces

If we could add text-based event points to trend traces, this would allow users to immediately understand what events occurred at specific times when they review past trend data and observe abnormal traces.
Keetanat Siriwat about 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Zooming in on plot results in visual change in binary Calculation from always 0 to sometimes 1 . Bug?

I implemented a PI Vision Calculation to implement a binary trend that shows a '1' spike when a value suddenly changes. My goal was to identify at a glance sudden changes for long x vs time plot time durations (those events happen to be very rare)...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Edit legends for XY Charts

This is already a capability for normal trends. It would be useful to be able to put in custom names for trends on XY charts and not be stuck to the default data point name.
Guest over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Using more complex calculations involving the current time ('*') variable.

I made a Pi page containing calculations from several assets in our system. The result gives a flat number. It would be even more helpful If I could slot that equation into the current time calculation formula. For example, instead of doing " '*'+...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold over 2 years ago in Edge Data Store / Historian 0 No status

Add more syntaxes (as in Excel for example)

Would add so many more useful graphs, tables and calculation available. For example add number of alarms going off, number of errors found, countifs, ifs and so on.