To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Browse data source model in AVEVA Adapter Configuration Utility for easier data selection

If my data source (such as an OPC UA server) exposes an asset model, then as a super user or administrator responsible for data selection with the AVEVA Adapter Configuration Utility, I would be able to browse it directly in the utility without in...
Clement Dekeyser about 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Additional columns to filter in data selection

As a super user or administrator responsible for data selection with the AVEVA Adapter for OPC UA and AVEVA Adapter Configuration Utility, I would need additional columns as filters: Path Description Data Type Min Max Engineering Units...
Clement Dekeyser about 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 4 years ago in AVEVA™ Adapters 4 Future consideration

Support outputs/write data from PI Adapters

No description provided
Allison Muraski over 4 years ago in AVEVA™ Adapters / General 4 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

PI Adapter for SNMP

Write a PI Adapter that supports the SNMP protocol and is capable of writing data to EDS, PI, and OCS.
Guest over 4 years ago in AVEVA™ Adapters / New Connectivity 4 Evaluating

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

JSONata libary in addition to JSONpath

If we could define stream parameters using JSONata it would allow for much more complex data selection, and allow for functions to be executed on data to pre-process in advance of writing to the OMF endpoint. This would ideally be available for an...
Mike Horrocks 2 months ago in AVEVA™ Adapters / General 0 No status

Make the portal pages 16:10 - not 4:3

This is the 21st century. The majority of users are using screens in a 16:9 or 16:10 aspect ratio, or will shortly do so. Why should a newly launched (!) portal be 4:3, and crop vital column contents e.g. in the "Products" section("PI Connector fo...
Guest about 4 years ago in Customer Portal & PI Square / Customer Portal Overall 1 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks almost 2 years ago in AVEVA™ Adapters / General 1 No status