To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My ideas

Showing 1492

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 2 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined

Expose methods to retrieve messages from the PI Message log to PI AF SDK

Add methods to retrieve messages from the local and remote PI Message Logs where remote can refer a PI Data Archive node or any remote PINS. Because the EventLog Class in .NET Framework provides access to local and remote Event Logs, offering th...
Guest over 2 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 3 Declined

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 over 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

As an avid user/admin of AF, in PSE I would like an option to display large attribute values with commas

Currently, in PSE there is no way to display attribute values greater than or equal to 1000 with commas for the thousands separators. Ex: 1,234,456 instead of 123456. This option exists in other PI Clients (i.e. PI Vision) and should be available ...
Guest over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined

DataLink features in Coresight

To get the functionality of the extensability, as for example spider chart or other charts, it is necessary to get timed data series in Coresight. For example hourly values with the syncronized timestamps from a series of PI tags. In general i wa...
Hobbe over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 Declined

Change text alignment in a Table symbol

Currently, text alignment is hard-coded in the Table symbol. I would like to be able to configure text alignment (right, left, center) for each column within a Table.
Guest over 2 years ago in AVEVA™ PI Vision™ / User Experience 3 Declined

Apply the Connector Relay to IEC 60870-5-104 Connector

Adding the Relay and the DCM framework to the "legacy"IEC 104 Connector in order to improve the architecture management and security
marcogiunti over 2 years ago in PI Connectors / Other specific PI Connector 1 Declined

Get Description from the OPC UA Server into the AF attribute

Get Description from the OPC UA Server into the AF attribute
Gabriel Verreault over 2 years ago in PI Connectors / PI Connector for OPC UA 0 Declined

Support for Alarms and Conditions

We need to be able to handle Alarms and Conditions into the PI system. We are moving away from OPC classic into OPC UA.
Hobbe over 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

AF Transformer sync functionailty

1. AF Transformer should be able to sync changes made in the source AF Database: if an element is added, deleted or edited.  For the deletions there should be a way to select the behavior: delete an object from the target database, place it u...
Guest over 2 years ago in AVEVA™ PI Server / General 0 Declined