Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 302

SNMP: Throttle scan specific informational messages as the interface may fill up logs every scan frequency

This is for SNMP version 1.6.3.0, the following message is printed every scan frequency: "Scan class for device will be skipped due to previous pending requests" And this needs to be throttled as the logs may be get filled up quickly with th...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

DNP3: store data as "bad"

Add functionality to treat the data as "bad" and send a digital state instead, when status flags are sent with the event and status bits are set to TRUE. Right now, the data is sent to PI and marked as "questionable". Note: This was previously En...
Clint Ramsey almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

Allow PI APS to rename PI Points

PI APS is now not able to rename a PI Point name. If the item name is changed on the Datasource side we wish that APS rename the Pi Point.
Guest almost 2 years ago in PI Interfaces / Other Interfaces 2 No Status

Add subscribeCOV support to BACnet Interface

My device only supports SubscribeCOV, but the PI Interface for BACnet only supports SubscribeCOVProperty. I would like the PI Interface for BACnet to support SubscribeCOV like the PI Connector for BACnet already does.
Guest almost 2 years ago in PI Interfaces / Other Interfaces 2 No Status

CA ISO Interface - Allow conversion of timestamp values (i.e. InstructionStart) from UTC to local time

Currently, the interface does not have any means to convert timestamp values (i.e. not the actual timestamps corresponding to values), such as InstructionStart, to account for timezone differences.  Therefore, the timestamps have to be manually ad...
Guest almost 2 years ago in PI Interfaces / Other Interfaces 0 No Status

64-bit version of CatGH5 interface

There needs to be a 64-bit version of the CatGH5 interface that is capable of parallel processing in order to efficiently process an quantity of data/files (that the 32-bit version is not up to the task of handling well).
Guest almost 2 years ago in PI Interfaces / Other Interfaces 2 No Status

PI Interface for Foxboro I/A 70 Series should support Windows 10

On PI Interface for Foxboro I/A 70 series version 2.4.2.12, the supported operational System are Windows 2008 R2, Windows 7, Windows 8 and 8.1, Windows 2012 Server. Can we also test the interface against Windows 10, to included it as a supported OS?
Guest almost 2 years ago in PI Interfaces / Other Interfaces 1 No Status

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco about 1 year ago in PI Interfaces / PI Interface for OPC DA 1 No Status

Enable logging of 5.x batch interface messages to the local PI message log again

Message logs for 5.X Batch interfaces and Connectors are written to Windows Event Viewer instead of PI Message Logs as in previous versions. The Windows Event Log is extremely slow compared to viewing PI message logs, the filtering is worse, the m...
Guest 11 months ago in PI Interfaces / Batch Interfaces 2 Declined

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest 11 months ago in PI Interfaces / PI to PI Interface 0 No Status