Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 386

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 0 Declined

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Import function for data selection in PI Data Data Collection Manager

During setup of a new data source we always face a long list of several thousand tags where we only need a couple of hundred. We have also a list with tagnames available as .xlsx or similar. The idea is to have an import function for that list to ...
Guest over 2 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Allow the PI Connector for UFL to call a REST endpoint using the POST method

I have come across customer requirements asking for the possibility of calling a REST endpoint using POST, from a PI UFL connector running as a "REST Client". So far, the workaround has been to develop an intermediary custom script which would ca...
Guest over 2 years ago in PI Connectors / PI Connector for UFL 0 No status

PI Connector for SKF Vibration Monitoring

Develop a connector for SKF Vibration Monitoring
Guest over 2 years ago in PI Connectors / New PI Connector Request 1 No status

Unit testing for Microsoft Edge browser for PI Connectors administration

The tested browser from AVEVA is Google Chrome. However, some organizations typically use an official browser or a proffered browser like Microsoft Edge. For such scenarios it will be a good idea if Aveva does the end to end unit testing for the o...
Aniruddha Kulkarni over 1 year ago in PI Connectors / PI System Connector 0 No status

Add Event IDs to event logging

Currently, events logged for the OPC UA Connector all have an Event ID of 0. I've had to dig around in Event Viewer quite a bit for troubleshooting, and it's frustrating not to be able to filter events by ID. I mention the UA Connector because tha...
Guest over 1 year ago in PI Connectors / General 0 No status

Create a PI connector/interface for devices communicating using the BACnet/SC protocol

The instance of the PI system that the group I work in is over 50% complete in integrating the JCI Metasys building control systems from 190 facilities. The software/firmware of the devices that comprise the JCI Metasys system we are using current...
Daniel Chiariello 5 months ago in PI Connectors / PI System Connector 0 No status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest 9 months ago in PI Connectors / PI Connector for OPC UA 0 No status