To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4906 of 4906

The PI Connector for Wonderware Historian should automatically populate the point attributes Zero and Span when creating PI Tags.

As a PI System Admin, I would like the PI Connector for Wonderware Historian to automatically populate the point attributes Zero and Span when creating PI Tags so that these attributes do not have to be manually edited after the tags are created.
Guest about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Allow PI system Connector to be Redundant

This product is pushing production data... it should be redundant.
taterhead247 about 2 years ago in PI Connectors / PI System Connector 2 No status

Enable child Event Frames for Alarms and Conditions from PI Connector for Siemens Simatic PCS 7

Would like to see states of alarms captured as child Event Frames of the parent alarm Event Frame that is currently created. Today this data is only captured in tags.
Guest about 2 years ago in PI Connectors / Other specific PI Connector 1 No status

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest about 2 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for Modbus TCP - include option to configure response data byte size by register type.

Certain RTUs limit the number of Boolean/Discrete values they return independently of the number of floats they return. The PI Connector for Modbus has a configuration option for “Maximum Response Data Bytes” but it applies to all register types. ...
Guest about 2 years ago in PI Connectors / Other specific PI Connector 0 Declined

Description

The OPC UA connector automatically creates tag descriptions when new tags are loaded (tag only mode). This behaviour may not always be desired . In our example we want to change the descriptions to something more meaningful. It would be useful to...
tdeibe01 about 2 years ago in PI Connectors / PI Connector for OPC UA 1 Evaluating

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Improve AF Transformer PostProcessing logging and performance

PostProcessing stage of the transformation (if using ParantID and ElementID) should use paging (or another approach) for a better performance, it should also be better logged and display number of objects processed, a number of objects in the list...
Guest about 2 years ago in AVEVA™ PI Server / General 0 Declined

Manual Logger display previous tour values.

You can se last archived values under tag in the PI Manual Logger Web, however if you already passed some tours before, but not uploaded them to PI Data Archive yet, you would like to see these values as latest values too.
Guest about 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 Declined

PI Manual Logger: Support for Multiple PI Servers/Collectives

Support for multiple PI Data Archives/Collectives for one instance of PI Manual Logger.
Ryan McErlean about 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status