Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1461 of 5193

Let subscribers set timezone for alerts

As a notification subscriber I want alerts to be sent using timestamps in my timezone so that I don't have to do mental conversion to interperate an alert.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 3 Declined

Add support for multiple SortFields in AF Search

Currently, AF search results can only be sorted by a single field. It would be useful to have the capability to specify 2 (or more) SortField values so that the order of results can be guaranteed in the result of a tie. For example, being able to...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Transformation and Scaling for OPC UA Adapter

Implement transformation and scaling for OPC UA adaptor the way it exists for PI OPC DA interface tags. The user can modify egressed tags and the data will be transformed / scaled when egressed.
Guest over 3 years ago in AVEVA™ Adapters 3 Future consideration

PI Adapter for SNMP

Write a PI Adapter that supports the SNMP protocol and is capable of writing data to EDS, PI, and OCS.
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 3 Evaluating

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 2 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 2 years ago in AVEVA™ Adapters / General 5 Future consideration

Extend PI audit trail to include changes made to snapshot using SMT

Using the SMT tool with the PI archive editor you can enter current values using * as time. This enters directly into the snapshot but is not recorded in the audit trail. All changes made should be recorded
Carl Van Laer over 3 years ago in AVEVA™ PI Server / General 0 No status

Delay Real-Time Calculations until backfill is finished.

For recursive Analyses such as below : PrevVal(tagA,'*') + 'TagB' → output : tagA When the PI Analysis Service is down (or the node needs to be restarted), the current calculation needs to be halted until the Backfilling reaches up to the start u...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status