Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 57

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 almost 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

Get Description from the OPC UA Server into the AF attribute

Get Description from the OPC UA Server into the AF attribute
Gabriel Verreault almost 2 years ago in PI Connectors / PI Connector for OPC UA 0 Declined

Get data by polling

Support acquiring data by polling the OPC UA server rather than subscription.
Guest almost 2 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

OPC UA: allow a host name override

Allow a hostname override when connecting to the OPC UA endpoint.   We have some use cases where the URL returned by two independent OPC UA servers has the same name.  This prevents the Connector from connecting to the correct endpoint. Allow an I...
Clint Ramsey almost 2 years ago in PI Connectors / PI Connector for OPC UA 6 Declined

Transformations and scaling

Add the ability to configure PI points so that the PI Connector for OPC UA performs transformations and scaling on the values before being archived.
Guest almost 2 years ago in PI Connectors / PI Connector for OPC UA 2 Declined
322 VOTE

Connector-level Failover - OPC UA 2.x

Support connector-level failover in PI Connector for OPC UA 2.x (relay-enabled version). Similar to UniInt failover (interfaces), failover should be data source specific and always favor the data source in the better state.
Gabriel Verreault almost 2 years ago in PI Connectors / PI Connector for OPC UA 35 Declined
205 VOTE

Monitoring Connector health

Support for health tags (similar to UniInt health tags), Windows performance counters, or any other way to bring Connector status and health information into PI tags to put them side-by-side with Interface health monitoring.
Guest almost 2 years ago in PI Connectors / General 42 Declined

PI Connector for IEC 60870-5-104 bi-directional between SCADA and PI

RWE Power AG “But one really important feature we need, is the ability to write back from PI into the SCADA system Until now, we couldn’t find anything about this (important) functionality. So our question is if we can use this connector bi-dire...
Guest almost 2 years ago in PI Connectors / General 4 Declined

Output tags on connectors

Sometimes we need to send data back to our sources. Connectors should support output tags
Alan Izar almost 2 years ago in PI Connectors / General 8 Declined

Allow restarting on a data source basis instead of having to restart the connector

Example 1 - OPC If a new connection needs to be made to one OPC Server, restarting the connector forces all data sources (and potentially connections to multiple OPC Servers) to be restarted. Example 2 - UFL If my web service is down and I do...
Gabriel Verreault almost 2 years ago in PI Connectors / General 3 Declined