To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 400

amqp

Support AMQP over Websockets to allow streaming to Azure IoT Hub using only HTTPS/port 443 to be more compatible with firewalls and proxy servers.
Steve Boyko over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Allow option to include SYSTEM Digital State in value column

Currently, whenever there is a SYSTEM Digital State written to a PI Point attribute, the PI Integrator for BA will output a null and to be able to publish the state value, an additional data column for status needs to be added. It would be nice ...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Streaming views without time delay

Messages sent to Kafka targets from streaming views are sent in batches, which causes unwanted delay for the first created messages in the batch. Our users need the streaming data without delays. Send the messages as they are created, without time...
StefanFors over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add functionality to change the name of a PI Integrator publish target after its creation

Please add functionality to change the name of a PI Integrator publish target after its creation. For example, a SQL target was named after its server hostname. After the SQL server migration to a new server with a new hostname, we'd like to updat...
Ting-Ying Chung about 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

remove case sensitivity from alphanumeric ordering

the PI Integrator is case sensitive in it's alphabetical ordering which doesn't appear to be common with any other PI tools. it can cause weird looking asset views that would otherwise look normal in say asset framework
meschenbruch over 2 years ago in PI Integrators / General 0 No status