Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 4926

Bulk Update PI Vision Hyperlink URLs

As of now users who migrate their PI Vision and PI Vision Displays to a new environment have no convenient way of updating the hyperlinks on those displays. This is not an issue for users with Administrative access, but lower permissioned users ar...
zachary cmelak 4 months ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 No status

Have programmatic API and framework kit for Integrators

Many partners we work with would like to be able to configure views and data output from PI Integrator for BA directly from within their Analytics tools. This could also allow for better integration with third party analytics tools and open an OEM...
Guest over 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Create a programmatic access layer

Customers have been using DLResize in the VBA pidldialogs.xla project which is unsupported. It would be nice to create a programmatic access layer so that things such as DLResize can be done in a supported way. It would also be helpful to have pro...
Guest over 2 years ago in AVEVA™ PI DataLink™ / Programming 1 Declined

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 6 No status

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest over 2 years ago in Developer Resources / Open Message Format (OMF) 2 No status

Adding several Events Id in the URL to open display for a direct batch comparison

It could be useful to open the Batch Comparison display with a list of batches (Unit Procedures or lower level) directly. This list would come from the result of a query inside a third part tool, like a MES. In the PI Vision URL, it could be a con...
Hervé Bajolle over 1 year ago in AVEVA™ PI Vision™ / Event Comparison Displays 0 No status

Simplify the security configuration for OPC UA

The newer OPC UA protocols have stricter security standards, which is good, but that makes configuring connections more difficult, especially with regard to the need to put in tunneling and open ports. It should be easier to establish a secure con...
Laurie Dieffenbach about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,
Guest over 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane over 2 years ago in PI Connectors / PI Connector for OPC UA 4 No status

% good property of rollup analyses

As a user, I would like to configure my rollups to display a value only if the quality of my inputs reaches a minimum % good (configurable). Currently, it's not clear which inputs are used in the rollup calculation- even if some inputs have bad va...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status