To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Notification/Event Acknowledgement: Support 21 CFR Part 11 Electronic Signatures

Include functionality to support the pharmaceutical industry electronic record and electronic signature requirements (21 CFR Part 11) when acknowledging an event or notification, when setting a reason code, and when commenting. This would require ...
Guest about 4 years ago in AVEVA™ PI Vision™ / Manual Data Entry 7 Declined

Remove installation kits' dependency on write permission to root C:\.

Some organizations do not provide admin accounts with write permission to the root C:\ directory. The install kits of most PI products copy the setup.ini to C:\pisetup.ini, and then write the logs to C:\ before moving them to %pipc%\dat, both of w...
Guest about 4 years ago in AVEVA™ PI Server / Installation 4 No status

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 about 4 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest about 4 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Scheduled backfilling for a specific time frame on analyses

Add the capability to perform scheduled backfills for a specific time frame, for analyses created on PI System Explorer.
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 9 No status

Enable tracing for one individual Analysis

On a highly loaded system with thousands of analysis i have one analysis that is misbehaving, missing executions but no skipped count, etc. Currently tracing enables tracing for ALL analysis creating an ocean of logging to plough through for that ...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Acknowledge of Event Frames requires Reason Code / Comment / Electronic Signature

It should be possible to configure event frames to be acknowledgeable only if a comment/reason code is entered before. we have this requirement sometimes in life science industry, but i can imagine it might be also usefull in other industries (e.g...
FranzK about 4 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status

Be able to reorder components

As an AVEVA Adapter gets used more, some components might need to be added or deleted, which can leave the component list in a suboptimal order. Please allow the components to be reordered, ideally by clicking and dragging for the most frictionles...
Kenneth Barber about 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

Do not have data entry where only 1 choice is allowed (e.g. component type when adding a new component)

In the AVEVA Adapter Configuration Utility, when you try to add a new component to an AVEVA Adapter, you get a dropdown menu for the component type. However, there is only 1 choice: the AVEVA Adapter component type. The only required instance of t...
Kenneth Barber about 2 months ago in AVEVA™ Adapters / AVEVA Adapter Configuration Utility 0 No status

For PI Points created by AVEVA Adapters, use the point class "base" instead of "classic" if the PI Point does not use "classic"-specific PI Point attributes

When an AVEVA Adapter creates a new PI Point, it always uses the point class "classic", even if none of the attributes that are specific to this point class are ever used. Instead, AVEVA Adapters should create PI Points using the point class "base...
Kenneth Barber about 2 months ago in AVEVA™ Adapters / General 0 No status