Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 378

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest 2 months ago in PI Connectors / PI Connector for OPC UA 0 No Status

Connector should rescan UA server, on a configureable basis, for new objects already defined in CSV file

It would be helpful if the UA Connector could rescan the UA server for new objects that have already been selected in the AvailableTypeDefinitions file and add them to the server on a configurable frequency.  We primarily use the UA Connector for ...
Steve Hampton almost 2 years ago in PI Connectors / PI Connector for OPC UA 2 No Status

Merge Two Tags or Copy Tag Data to a New Point

Sometimes, when dealing with APS, a new TAG is generated for an existing point. Data stops going to the old point. It would be nice if there was an easy way, within the gui (not manually dumping and importing) that we could take the values from on...
Guest almost 2 years ago in PI Connectors / General 4 Declined

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Poi...
Guest almost 2 years ago in PI Connectors / Other specific PI Connector 1 No Status

Remove or disable the PI Connector UFL function which puts "Excluded" into attributes

If the user has two different UFL flows working on same elements and attributes, one flow puts "Excluded" into the attributes created within the second one and vice versa. Giving the possibility to the user to disable this function would be a sma...
rodolforotti almost 2 years ago in PI Connectors / PI Connector for UFL 1 Declined

Add possibility to Configure purge time/output path/REST channel authentication in the admin/ui webpage without GlobalConfig.ps1

It's more complex and not the safest way to change the PurgeTime and OutputPath parameters with GlobalConfig.ps1 by specifing password in command line. It would be better if this option would be availble for UFL admin on the admin/ui webinterface....
Yuriy Sadovskiy about 1 month ago in PI Connectors / PI Connector for UFL 0 No Status

OPC UA bi directional communication

like the PI Interface OPC DA, it would be good to have the possibility to read and write value back to the source system.
Pascal_13 4 months ago in PI Connectors / PI Connector for OPC UA 0 No Status

Connector (UFL) can read AF data structure

Right now it is a limitation because of the current functionality / design. In the future it would be nice if: - the connector can read the existing AF structure - update the existing AF structure - create elements / EF / attributes under existin...
Guest almost 2 years ago in PI Connectors / PI Connector for UFL 1 Declined

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest almost 2 years ago in PI Connectors / Other specific PI Connector 3 No Status

Install and configure more than one PI System Connector instance per server

At local industrial sites, we deploy use cases different in nature and end user consumption in separated AF DBs, like OEE, PSM, Autoclave, utilities, etc. We need to centralize these individually into our central PI System. We need to segregate th...