To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 378

Allow options to alter the way the connector handles different qualities (bad, questionable)

At this time, the connector does not expose any way to alter the way data of different qualities (bad, good, questionable) is handled. The PI OPC Interface allows several different options with regards to “quality” such as "send only GOOD quality ...
Gabriel Verreault over 1 year ago in PI Connectors / PI Connector for OPC UA 1 Declined

Support for Alarms and Conditions

We need to be able to handle Alarms and Conditions into the PI system. We are moving away from OPC classic into OPC UA.
Hobbe over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No Status

Connector should rescan UA server, on a configureable basis, for new objects already defined in CSV file

It would be helpful if the UA Connector could rescan the UA server for new objects that have already been selected in the AvailableTypeDefinitions file and add them to the server on a configurable frequency.  We primarily use the UA Connector for ...
Steve Hampton over 1 year ago in PI Connectors / PI Connector for OPC UA 2 No Status

Merge Two Tags or Copy Tag Data to a New Point

Sometimes, when dealing with APS, a new TAG is generated for an existing point. Data stops going to the old point. It would be nice if there was an easy way, within the gui (not manually dumping and importing) that we could take the values from on...
Guest over 1 year ago in PI Connectors / General 4 Declined

OPC UA bi directional communication

like the PI Interface OPC DA, it would be good to have the possibility to read and write value back to the source system.
Pascal_13 3 months ago in PI Connectors / PI Connector for OPC UA 0 No Status

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Poi...
Guest over 1 year ago in PI Connectors / Other specific PI Connector 1 No Status

Remove or disable the PI Connector UFL function which puts "Excluded" into attributes

If the user has two different UFL flows working on same elements and attributes, one flow puts "Excluded" into the attributes created within the second one and vice versa. Giving the possibility to the user to disable this function would be a sma...
rodolforotti almost 2 years ago in PI Connectors / PI Connector for UFL 1 Declined

Connector (UFL) can read AF data structure

Right now it is a limitation because of the current functionality / design. In the future it would be nice if: - the connector can read the existing AF structure - update the existing AF structure - create elements / EF / attributes under existin...
Guest almost 2 years ago in PI Connectors / PI Connector for UFL 1 Declined

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 1 year ago in PI Connectors / Other specific PI Connector 3 No Status

Install and configure more than one PI System Connector instance per server

At local industrial sites, we deploy use cases different in nature and end user consumption in separated AF DBs, like OEE, PSM, Autoclave, utilities, etc. We need to centralize these individually into our central PI System. We need to segregate th...
Christian Leroux over 1 year ago in PI Connectors / PI System Connector 0 No Status