Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Modifying an integrator view should lead to its target conserving already existing historical data

Currently, if an integrator view is already created on a target (for example SQL) and then a user needs to modify the view to add one or more columns to the target table - A fresh table will be created for the modified view containing the newly ad...
Guest 7 months ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Export data from the Display Sessions to a PI Point through an interface or performance counter

The Display sessions are very useful for daily monitoring. But having the option that allows us to save the data from this utility to a PI Point or attribute for later analysis would be useful for monitoring purposes
Guest over 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 11 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
Philipp Even almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
Philipp Even almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Generic access to Customer Portal until user added to site

We need the ability for a user to gain generic access to the Customer Portal until they are added to a specific site. We have users who create an SSO themselves but can't submit a case until they get added to a site (generic No Access received). ...
bhilgemann almost 4 years ago in Customer Portal & PI Square / Customer Portal Overall 1 No status

Expose PI Network Manager Statistics via AF SDK

As of now, we can get PINetMgr statistics via PowerShell command Get-PIConnectionStatistics. # of users familiar with AF SDK are more than with PowerShell. It will be nice feature addition in AF SDK, and usability will also increased.
Guest almost 4 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 1 Declined

Starting a Backfilling / Recalculation from a web interface using the Web API

We need a simple interface to modify data in the PI DA and restart calculations based on this data. For this we plan to develop a web interface, using the Web API. Modifying data is not a problem. But making a backfilling is more difficult. Back...
JMarc almost 4 years ago in AVEVA™ PI System Access (PSA) / PI Web API 0 No status

OPC UA Connector Trend Advise Option

OPC UA Connector Trend Advise Option, such as in the UniInt interfaces
Guest almost 4 years ago in PI Connectors / PI Connector for OPC UA 5 No status

Have option to enable exception on Connectors.

There are use cases where data is sent over networks with latency (satellite link, for example) so being able to filter out noise at the connector is important.  This is also important when a connector sends data to a local PI Server in the f...