To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

PI Connector for ICCP

Implementation a connector that supports the ICCP TASE 2 protocol
marcogiunti over 4 years ago in PI Connectors / New PI Connector Request 2 Declined

OPC Alarms&Events interface should natively support event frame creation

As a PI Interface for OPC Alarms & Events user that would like to leverage AF Event Frames for more advanced analysis, I would like for the OPC AE interface to have an option to natively create event frames that open when a Status = Active mes...
Guest over 4 years ago in PI Interfaces / Other Interfaces 2 No status

Support float64 point type in PI Interface for China Network Isolator

China Network Isolator interface does not support float64 point type, which is required by many customers in China. Right now, they have to change the point type to string first and then to float64 by analytics, this will consume two times of lice...
Guest over 4 years ago in PI Interfaces / Other Interfaces 3 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / General 2 No status

Adapter for BACnet - defaultStreamIdPattern add ObjectName as possible parameter

Currently, for the Adapter for BACnet its [Data source parameters] defaultStreamIdPattern does not have an option to include the ObjectName in the defaultStreamIdPattern. It would be good to include this as a possible parameter for the defaultStre...
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Improve Attribute Filter Logic in Asset Comparison Table to Distinguish Between Digital States and Numeric Values

In PI Vision, when using dynamic search criteria in an Asset Comparison Table, attribute filters such as "Drive_G >= 15" can produce misleading results because PI Vision does not differentiate between digital states and actual numeric values. D...
Guest over 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status

Link to other displays within Folder Navigation structure

We have made a display for one department that would be helpful to view in another department. Instead of copying the display to our folder, it would be better to link to the other display to maintain only 1 display to be updated. I would like to ...
Parker Shaw over 1 year ago in AVEVA™ PI Vision™ / Display Management / Displays Page 2 No status

Dump all tags from a point source, select all, display point values with timestamp

In PI ProcessBook, when defining a trend, you could perform a tag search dumping all tags tied to a particular point source, and then select all tags and get the point values and timestamp of last update and scroll through the entire list. This is...
Chris Swiecicki over 1 year ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

support the use of the following OPC UA specification modes: Maintenance, NoData, Degraded and Healthy

Reading the OPC UA specification, the possible value ranges are Maintenance, NoData, Degraded and Healthy. The PI OPC UA Server should support and provide the use all these modes and the conditions to trigger them And setup the Maintenance mode
serge claver Sambo Onana 2 months ago in AVEVA™ PI System Access (PSA) / AVEVA PI OPC UA Server 0 No status

Improve Product Search

Remove the need to know in which sub-group a product is hiding. If I for example want to install the PI System Connector, the Connector Relay,and the DCM, I first have to find out that the Connector and the Relay are in the PI Collection Suite, wh...
phsutterRoche about 4 years ago in Customer Portal & PI Square / Customer Portal Overall 1 Evaluating