To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 5197

OPC Alarms&Events interface should natively support event frame creation

As a PI Interface for OPC Alarms & Events user that would like to leverage AF Event Frames for more advanced analysis, I would like for the OPC AE interface to have an option to natively create event frames that open when a Status = Active mes...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Provide easier workflow to retrieve the recorded values for EF attribute

As a DataLink user, I would like to see all the values of the event frame attributes during the start and end time using the Explore Events function so that I don't need to ask for the compressed values during that time range for each of the attri...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Events (EF) 2 No status

Ability to quickly add "Filter Expression" on adhoc

Will it be possible to improve the AdHoc capabilities to allow adding the "Filter Expression" instead of trying to create a calculated value in PI Vision and then dragging into a trend and finally saving the trend?
Kimlin Pen about 2 months ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 0 No status

Add Function to Determine if a Bit is Active in a Word Value

It would be extremely helpful if a function existed within PI AF where could provided a value/tag reference and a bit number to check and see if its active. The function would return a True or False value if that bit is active. Something like the ...
Justin Jackson about 2 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Idle Logout

The user is requesting an idle logout setting so that if no activity is detected for a few minutes, the session will automatically end. Without this feature, there is an audit concern, as any unattended and active session could remain open and be ...
Khai On Yeap 4 months ago in AVEVA™ PI Vision™ / Security 2 No status

Support for Key Pair Authentication

Currently, PI ICU authentication relies on traditional username/password methods. However, this authentication approach is becoming increasingly obsolete and is not supported by many of the modern platforms and security frameworks we are required ...
Kareema Ramli 4 months ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Fix issue where the Time Bar Control not responding on trends with Custom Time range

When someone create a Trend in a PI Vision display and customize the Time Range (should be different than 8h), the PI Vision display show data ok, but if someone try to update the Time Bar Control setting to one option available (we have to select...
Edgar_Diaz 8 months ago in AVEVA™ PI Vision™ / Navigation 0 No status

Hide event attributes table from PI Vision event details display

Possibility to hide related attributes table below PI Vision event details display
Guest 8 months ago in AVEVA™ PI Vision™ / User Experience 0 No status

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Enable Table-Valued Functions to use parameters more than once

Currently Table-Valued Functions only support the use of a parameter once. For example, once the parameter has been used in another table Valued function like: ... crossapply Master.Element.GetSummary <...> (e.ID, @StartTime, @EndTime) I am ...
Frederik Reinhard 10 months ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status