To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ Adapters

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins over 2 years ago in AVEVA™ Adapters / General 2 Already exists

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Design some UI for PI Adaptors

Design some UI for PI Adaptors, so it will be user friendly to configure the data source or data reading configurations etc. It is really hard to configure or troubleshoot an issue in PI Adaptor without Proper UI.
PradeepKumar Logandurai over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Allison Muraski almost 4 years ago in AVEVA™ Adapters / General 3 Tell us more

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 3 Tell us more

Add a parameter for the Adapter to increase the Keep-Alive wait time

Currently, there is no parameter on the Adapter side to increase the Keep-Alive wait time. It would be best to add parameter for the Adapter to increase the Keep-Alive wait time.
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Egress via AF SDK

Please add AF SDK Egress as an additional optional egress component. This would be very helpful for customers who are using the adapters, but keeping the PI Server on-premise. The adapters are relatively light-weight services; however, the “cost” ...
sahilp 12 months ago in AVEVA™ Adapters / General 1 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status