To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Connectors

Showing 331

Allow PI system Connector to be Redundant

This product is pushing production data... it should be redundant.
taterhead247 over 3 years ago in PI Connectors / PI System Connector 2 No status

Enable child Event Frames for Alarms and Conditions from PI Connector for Siemens Simatic PCS 7

Would like to see states of alarms captured as child Event Frames of the parent alarm Event Frame that is currently created. Today this data is only captured in tags.
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Import function for data selection in PI Data Data Collection Manager

During setup of a new data source we always face a long list of several thousand tags where we only need a couple of hundred. We have also a list with tagnames available as .xlsx or similar. The idea is to have an import function for that list to ...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Allow data sources and servers to be renamed

Currently, if you want to rename a data source, PI Data server, or PI Asset server, you must delete the one with the old name and create a new one with the new name, and redo all of the configuration. This is especially a pain for data sources, si...
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

Allow the PI Connector for UFL to call a REST endpoint using the POST method

I have come across customer requirements asking for the possibility of calling a REST endpoint using POST, from a PI UFL connector running as a "REST Client". So far, the workaround has been to develop an intermediary custom script which would ca...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Allow users to rename PI Connector for UFL point source

PI Connector for UFL allows for configuring point prefix, but does not allow for modifying point source. Some users prefer browsing tags by point source, and may want separate point sources for different UFL connectors.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 2 No status

Create a connector for Profinet

Profinet is an industrial protocol which communicates over Ethernet. It offers a number of desirable features and functionalities which many of our customers find, or will find as the protocol becomes more widespread, very useful for collecting da...
Guest over 3 years ago in PI Connectors / New PI Connector Request 2 No status