To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: AVEVA™ Adapters

Showing 93 of 3181

PI Adapter for OPC UA should support Specific DA Tag Naming

As we are using an ISO based tag naming, we would like the PI Adapters to be able to write OPC UA Tag value into Specific tags in DA and not only in automaticaly created tags. Automated DA tag creation should be a possible choice, not the standard.
Fred_EYRAUD over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Completed

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for OPC UA data filtering based on OPC status codes

Currently, the PI Adapter for OPC UA sends good quality data to the configured data endpoint with no way to filter on different good quality statuses. There are several OPC status codes that fall under the Good Quality Data classification. When ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Completed

PI Adapter for MQTT's Sparkplug B component should allow for data messages to be sent without metric names

According to the Sparkplug™ MQTT Topic & Payload Specification Rev 2.2 on page 43 (https://www.eclipse.org/tahu/spec/Sparkplug%20Topic%20Namespace%20and%20State%20ManagementV2.2-with%20appendix%20B%20format%20-%20Eclipse.pdf), metric names sho...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 Completed

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive