To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 85 of 5194

EnumerationSet reference in RTQP

Within RTQP we cannot read the definition of EnumerationSet, this is a nonsense since this information is accessible through OLEDB Enterprise, and this information is really key for multiple integration topics
dgenet about 2 months ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett almost 2 years ago in PI Interfaces / Batch Interfaces 2 Planned

Be able to use RTQP to access PI Points and Config strings (DA Directly)

Be able to use RTQP to access PI Points and Config strings (DA Directly) Use case: create a dashboard that lets me know the amount of bad data (tags) mapped to our AF. (eg. “Bad Input”, “Calc Failed”, etc) Our system has numerous tags and it is ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 4 No status

Expose Event Frame Annotations in PI SQL DAS (RTQP Engine)

I would like the ability to access event frame annotations using PI SQL Client, in the same way as in PI OLEDB Enterprise.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 13 Declined

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 2 No status

Enable Table-Valued Functions to use parameters more than once

Currently Table-Valued Functions only support the use of a parameter once. For example, once the parameter has been used in another table Valued function like: ... crossapply Master.Element.GetSummary <...> (e.ID, @StartTime, @EndTime) I am ...
Frederik Reinhard 10 months ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

PI SQL Client to make use of the RecordedValue method and Retrieval Modes for the GetValue transposed function

When making use of the GetValue transposed function when creating a new Template specific Data Model, we can see that under the hood it makes us of the AF SDK call AFData.InterpolatedValue method to capture the data at a specified timestamp provid...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 1 No status

Add data reference impersonation for value retrievals

When retrieving values for attributes, impersonating the user can enable the user of security at the data source level. For example, with a PI Point Data Reference attribute, it could allow the user's authorization to be user at the data archive r...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Batch Framework Interfaces - [TIME] placeholder should consider whether TS=LCL is configured

Batch Framework Interfaces - [TIME] and [TIMESTAMP] placeholders should consider whether TS=LCL is configured (meaning the interface is processing incoming events as Local Time). Currently, values of these placeholders always show up as GMT timest...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 5 Planned

Support Werum PAS|X 3.2 and PAS|X Data Access (PDA)

Werum has recently released the next version of their PAS|X Database, and it bolsters a new method of Data Access. OSIsoft will need to release an re-tooled version of their PI Interface for Werum PAS|X to support this latest Werum version and the...