To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 149 of 5194
109 VOTE

"Outputs at Start"group

It would be nice if there were an "Output at start" option to output values at the start of an event frame. Currently there is an "Outputs at close" option for Event Frames.
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 39 No status

PI EF security trait/context

We are trying to standardize and mutualize all of our templates but we want to keep the security well defined : in general it work perfectly when things are in read only mode. Where write access is needed everything looks good for Elements since t...
dgenet 3 months ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Automatic Recapture Values for Event Frames

I would like to have the possibility of automatically recapturing values for event frames, so if the lab data comes in after the events are generated the late values could be recaptured automatically and in bulk. This will save the time and effort...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Allow parameters to be passed to a request body in the Batch Controller

I would like the ability to pass response values from one request into the body of a dependent request using the batch controller to avoid making 2 calls to the PI Web API. Currently,  I can only use Parameters in subsequent URLs, but not bo...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 1 Declined

Allow different naming for Parent and Child Event Frames

Allow a different naming pattern for the child event frames. End result would have the long, uniquely named EFs in the Parent EF as usual, but the Child EFs could have a simplified name, like the level of an alarm that is pulled from an attribute ...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 7 No status

late notification

At times I have event frames that generate late for various reasons that trigger a notification. Since it was late we have no need to get the notification. I would like a way to not have a notification trigger if it is late.
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 Tell us more

PI WEB API - Swagger page

It would be great if as an addition to conventional documentation there was a SWAGGER page with short explanation of methods and parameters (including return types, etc.)
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 2 No status

Allow selection of output timestamp for values written by the outputs at close feature in Event Frames

It would be nice to have the option to select either starttime or endtime of the eventframe as the timestamp for the value that will be written a PI tag using the Outputs at close feature in Event Frames. Currently, it will only write the value wi...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 5 No status

Custom Severity Levels for Event Frames (EF) Triggers

Enable the ability for end-user to manage custom severity levels for event frames, to allow for better communications across response teams and business unit functions. Exposing EF severity levels within a PI Notifications messages is very helpfu...
jtepfer@ebay.com over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Implement a checkpoint system for index crawls

When the crawler fails on an incremental crawl, the index search must perform a complete rebuild of the index. It would be beneficial for there to be a way to revert to a previous built index just prior to the failed incremental crawl so that the ...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI Web API 2 Declined