AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 11 of 5194

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Rename "Compressed Data" to "Archived Data"

In the PI DataLink tab in the Ribbon, "Compressed Data" should be renamed to "Archived Data" since it actually retrieves archived data and not just compressed data. The icon should also be changed accordingly. Not all data in the PI Data Archive n...
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Rename "Timed Data" to "Data At Timestamps"

When I see "Timed Data", I think: "Well of course my data is timed! But what does this button do?". "Timed Data" retrieves interpolated/archived values at the given timestamps. Please rename "Timed Data" to better reflect this. I recommend "Data A...
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Replace "https://techsupport.osisoft.com" in PI DataLink's About window

The link redirects to myOSIsoft. The link should be revised so that it does not redirect and possibly so that it leads to a different page instead. Either that or the link can be eliminated entirely.
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 3 No status

Rename "Time Filtered" to "Condition Time"

"Time Filtered" was meant to be interpreted as "Time [Spent] Filtered", but it can easily be misinterpreted as "Time[-]Filtered" (i.e. filtered by time, i.e. Compressed Data). Please rename "Time Filtered" to "Condition Time" so that the name bett...
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Help / Documentation / Videos 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration