To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

General

Across all AVEVA Adapters, standardize the specification of time zones

Some AVEVA Adapters do not let you specify the time zone of the timestamp. Those that do let you specify the time zone do so inconsistently. For example, the AVEVA Adapter For Structured Data Files lets you specify a time zone from the IANA time z...
Kenneth Barber 12 days ago in AVEVA™ Adapters / General 0 No status

Support for additional Complex Data Types for all Adapters

Request to enhance the Adapters to support more complex data types, specifically value/quality pairs. While some Adapters currently support geolocation and coordinate complex data types, they do not all support value/quality data types. In industr...
Derek Wong almost 2 years ago in AVEVA™ Adapters / General 0 No status

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / General 1 No status

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 0 No status

Allow multiple instances of an AVEVA Adapter to exist on the same server without using Docker

Currently, there can be only 1 instance of a specific AVEVA Adapter on each server if Docker is not used. However, within that instance, multiple components and data sources can be configured. This is convenient, but then the service account for t...
Kenneth Barber 5 months ago in AVEVA™ Adapters / General 0 No status

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi over 1 year ago in AVEVA™ Adapters / General 1 No status

Support outputs/write data from PI Adapters

No description provided
Allison Muraski over 4 years ago in AVEVA™ Adapters / General 4 No status

JSONata libary in addition to JSONpath

If we could define stream parameters using JSONata it would allow for much more complex data selection, and allow for functions to be executed on data to pre-process in advance of writing to the OMF endpoint. This would ideally be available for an...
Mike Horrocks 2 months ago in AVEVA™ Adapters / General 0 No status

Support "Data Handling" options for adapters

The PI Interface for OPC DA can write IO timeout when it cannot get values from the OPC server. It would be useful to have the same option for the adapters so that stale data is marked IO timeout or similar, and automatically invalidates calculati...
Mike Horrocks almost 2 years ago in AVEVA™ Adapters / General 1 No status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / General 3 No status