Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Event Frames (EF)

Showing 62
100 VOTE

"Outputs at Start"group

It would be nice if there were an "Output at start" option to output values at the start of an event frame. Currently there is an "Outputs at close" option for Event Frames.
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 37 No status

Automatic Recapture Values for Event Frames

I would like to have the possibility of automatically recapturing values for event frames, so if the lab data comes in after the events are generated the late values could be recaptured automatically and in bulk. This will save the time and effort...
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Allow different naming for Parent and Child Event Frames

Allow a different naming pattern for the child event frames. End result would have the long, uniquely named EFs in the Parent EF as usual, but the Child EFs could have a simplified name, like the level of an alarm that is pulled from an attribute ...
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 7 No status

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek about 2 months ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

late notification

At times I have event frames that generate late for various reasons that trigger a notification. Since it was late we have no need to get the notification. I would like a way to not have a notification trigger if it is late.
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 3 Tell us more

Allow selection of output timestamp for values written by the outputs at close feature in Event Frames

It would be nice to have the option to select either starttime or endtime of the eventframe as the timestamp for the value that will be written a PI tag using the Outputs at close feature in Event Frames. Currently, it will only write the value wi...
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 5 No status

Event Frame (EF) Linking

Ability to link Event Frames coming in from different sources (batch & mes interfaces, EFgen, PI Analytics, custom, etc.) together based on rules and monitoring an EF attribute SO THAT it's easier to associate time frame context and data that ...
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Aggregate event frames to a time series

As an user, I want to be able to treat event frame like time series data, such as number of active event frames, sum of an attribute, so that I can continuously monitor the evolution of event frames over time.
Guest over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Custom Severity Levels for Event Frames (EF) Triggers

Enable the ability for end-user to manage custom severity levels for event frames, to allow for better communications across response teams and business unit functions. Exposing EF severity levels within a PI Notifications messages is very helpfu...
jtepfer@ebay.com over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 4 No status

Acknowledge of Event Frames requires Reason Code / Comment / Electronic Signature

It should be possible to configure event frames to be acknowledgeable only if a comment/reason code is entered before. we have this requirement sometimes in life science industry, but i can imagine it might be also usefull in other industries (e.g...
FranzK over 2 years ago in AVEVA™ PI Server / Event Frames (EF) 2 No status