To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA™ Adapters

Showing 89
140 VOTE

Support Alarms and Conditions

We are evaluating support of Alarms and Conditions for a future release of the AVEVA Adapter for OPC UA. In order to get a better understanding of the user requirements and needs, please comment with the following of information: How do you collec...
Guest about 2 years ago in AVEVA™ Adapters / General 25 In development

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 No status

PI Adapter for OPC UA should be able to poll data from the OPC UA Server

Currently the PI Adapter for OPC UA only collects unsolicited advised data that is different from the previous value. We would need to see a polling feature to be able to: - Refresh slow moving streams with updates with the same value but differen...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 6 In development

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault about 2 years ago in AVEVA™ Adapters / General 3 No status

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support https instead of http only

No description provided
Gabriel Verreault about 2 years ago in AVEVA™ Adapters / General 1 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins 8 months ago in AVEVA™ Adapters / General 2 Already exists

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 Tell us more

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...