To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 12

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins 9 months ago in AVEVA™ Adapters / General 2 Already exists

Remove automatic asterisk at the end of a keyword in the PI Vision Tag Search

Currently PI Vision searches for all points with the given information in the Tag Search including any characters after the last character entered in the search assuming an automatic asterisk. We would like this automatic asterisk to be removed to...
duvenhage 3 months ago in AVEVA™ PI Vision™ / Search 1 Already exists

Move Displys from one folder to another folder

The User should be able to move a display from one folder to an other folder. often a folder structure is changed or someone needs new folders now your are not able to shift displays from the old folder to the new createt one.
SvenWagner 8 months ago in AVEVA™ PI Vision™ / Display Management / Displays Page 1 Already exists

Average calculation not working through Pi Vision Calculation editor

Time-based average (eg. 15min average) calculation not working through Pi Vision Calculation editor. Presently while using Avg('tag'), the result is only the instantaneous value at the end of 15 minutes, and not the average over 15 minutes.
AK over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 Already exists

Specific debug log levels to troubleshoot specific issues

Similar to PI Interfaces (/DB for opcint), adapters should allow setting some additional debugging to troubleshoot specific issues, instead of only allowing a general LogLevel (Information, Trace, Warning, etc.) This would allow for more granular ...
Gabriel Verreault over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Already exists

"Set as root" for PI AF Databases in PI Vision tree

When permitting PI AF Databases to PI VIsion in the PIVision\Admin tool, could there be an option to select an asset and "set as root" as you can do in PI System Explorer - so that the PI Vision users do not see the whole asset tree - but the asse...
Martin Bryant over 1 year ago in AVEVA™ PI Vision™ / AF Integration 1 Already exists

Duration should remain fixed and not get auto updated when changing end time of trend

When the end time of a trend (with duration 8 hours) is changed to an old date eg. 2 months back, the duration is getting re-initialized as the entire difference period eg. 2 months. This slows down data update highly. To prevent this, every time ...
AK over 1 year ago in AVEVA™ PI Vision™ / User Experience 2 Already exists

Standardize pointer for links on graphic

Im currently using a graphic (index, with buttons) from an operating plant DCS as a mimic on PI Vision. I want the user to click the buttons as they would on the DCS and the embedded link will take them to the display. I've discovered that using a...
Guest over 2 years ago in AVEVA™ PI Vision™ / User Experience 1 Already exists

Allow to set individual min-max when in multiscale on trend symbol

In Pi Processbook, it was possible to adjust the min/max for each tag even in multiscale mode. In PI Vision, it is not possible and our users require it.
jerome.boudon about 1 year ago in AVEVA™ PI Vision™ / Symbols 2 Already exists

Datalink tab opens when click on cell

When users click on any cell, it opens the tab on the right hand side and causes confusion. Setting it to manual opening will be easier to work with Excel page, have more space, and avoid confusion.
Gilbert Nassif over 1 year ago in AVEVA™ PI DataLink™ / Search 3 Already exists