AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 373 of 5284

More Database Options for PI Event Frame Generator

Allow configuration options for different databases via the PI Event Frame Generator. Being able to connect to a database via ODBC and then have a configuration file that would allow adding entries from that database as Event Frames would be very ...
Brian Rock 1 day ago in PI Interfaces / Other Interfaces 0 No status

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 29 days ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Interface for SNMP to support using all types of SNMPv3 encryption and authentication

Support for all types of encryption and authentication; namely AES-192, AES-256, and SHA-256 (and higher)
timothy chiles 10 months ago in PI Interfaces / Other Interfaces 0 No status
107 VOTE

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 9 Future consideration

Enable AVEVA Adapter for OPC UA to work with OPC UA Servers that only allow Dynamic Addressing and Virtual Browsing

Some OPC UA Servers have the concept of Dynamic Namespace Addressing and Virtual Browsing. The UA Nodes do not exist in the OPC UA Address Space. Nodeids are created\added to the Address Space only when a Client makes a request for the NodeIds thr...
Vaskar Dahal about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

1:1 Data Transfer Option in AVEVA PI2PI Interface

The AVEVA PI2PI Interface requires a new configuration option to enable a direct 1:1 data transfer from the source to the destination. This option must ensure that data is copied precisely as it is received from the source, without any modificatio...
Erik Prins 10 months ago in PI Interfaces / PI to PI Interface 0 No status

ICU startup on high latency networks

On high latency networks, it can take ICU many minutes to start because every interface on the PI Data Archive is checked. Minimize startup time by caching a node's registered interfaces.
Guest over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 11 Future consideration

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 In development

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett about 2 years ago in PI Interfaces / Batch Interfaces 2 Planned

Custom HTTP header

add functionality so will bepossible to configure the PI Adapter for OPC UA to include a custom HTTP header when authenticating requests to the PI Web API endpoint The request for this feature recently came up in a support case for PPC (Dev CR: CR...
Dimitrios Pilos 10 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration