Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 378

Add possibility to Configure purge time/output path/REST channel authentication in the admin/ui webpage without GlobalConfig.ps1

It's more complex and not the safest way to change the PurgeTime and OutputPath parameters with GlobalConfig.ps1 by specifing password in command line. It would be better if this option would be availble for UFL admin on the admin/ui webinterface....
Yuriy Sadovskiy about 17 hours ago in PI Connectors / PI Connector for UFL 0 No Status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest about 1 month ago in PI Connectors / PI Connector for OPC UA 0 No Status

PI System Connector - Support failover at the data source level

PI System Connector should be data source (collective aware) specific and always favor the data source in the better state. Furthermore, the PI System Connector should be able to determine whether data is stale on a given collective member, and au...
GaryYegiazaryan about 1 month ago in PI Connectors / PI System Connector 1 No Status

Connector level failover - PI System Connector

Support connector-level failover in PI System Connector. Similar to UniInt failover (interfaces). Failover options should support hot, warm and cold failover.
GaryYegiazaryan about 1 month ago in PI Connectors / PI System Connector 1 No Status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha about 2 months ago in PI Connectors / PI Connector for BACnet 0 No Status

BACnet SC/SuperConnect Support

Support for the BACnet SC/SuperConnect protocol for the PI Adapter, PI Connector, or PI Interface.
Connor Hawkins about 2 months ago in PI Connectors / PI Connector for BACnet 0 No Status

OPC UA bi directional communication

like the PI Interface OPC DA, it would be good to have the possibility to read and write value back to the source system.
Pascal_13 3 months ago in PI Connectors / PI Connector for OPC UA 0 No Status

Implement similar functionality as the /ta flag from the OPC DA interface

Using the OPC UA connector there is no equivalent to the /ta flag in the OPC DA interface, which ensures when a value significantly changes in a short time period that it does not interpolate. The current work around of setting the Step attribute ...
caffreys_col 3 months ago in PI Connectors / PI Connector for OPC UA 0 No Status

PI System Connector: Allow subset of event frames to be replicated

Currently you only have the ability to replicate ALL event frames and only if you want to replicate the entire AF database. We have one main AF database with many different types of event frames; however we do not want to replicate them all. It wo...
Rebekah_Wilson 3 months ago in PI Connectors / PI System Connector 0 No Status

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...
Guest 3 months ago in PI Connectors / PI Connector for BACnet 0 No Status