Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 302 of 4747

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett 7 days ago in PI Interfaces / Batch Interfaces 0 No Status

Batch Framework Interfaces - Officially support fanning tag data to a PI Collective

Unlike other PI interfaces, the Batch Framework Interfaces do not use buffering. If the interface loses connection to the PI Data Archive, the interface continues collecting data and stores it in its local cache. The PI Batch Database is primary-o...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 18 No Status

ICU startup on high latency networks

On high latency networks, it can take ICU many minutes to start because every interface on the PI Data Archive is checked. Minimize startup time by caching a node's registered interfaces.
Guest over 1 year ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 8 No Status

PI Interface for OPC UA

While it is understood that adapters are the future of data source connectivity; there is an immediate need for existing PI system users (especially in the Chemical industry) to transition their data sources from using OPC DA to OPC UA. Many of th...
Brian Rock 11 months ago in PI Interfaces / General 0 No Status

Remote PI ICU

Regardless of where interface info are stored (PI Module DB or AF), it would be useful to have a remote client tool allowing administrator users to configure interfaces  like they do with tags and AF objects. Today when you have to change configur...
MAl over 1 year ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No Status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 1 year ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No Status

Allow local files to be linked to Pi Vision Displays

It would be nice to have the ability to add navigation links to files saved to our computer for easier sharing in Pi Vision displays.
Travis Teigen 14 days ago in PI Interfaces / General 0 No Status

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 2 No Status

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest over 1 year ago in PI Interfaces / Batch Interfaces 2 No Status

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 3 No Status