To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 19

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett 11 months ago in PI Interfaces / Batch Interfaces 2 Planned

Update PI Web API with AF SDK supporting .NET 8

With the announcement of a new .NET 8 AF SDK at AVEVA World 2023 coming sometime in 2024, we would like to see a new version of the PI Web API that adopts this new version.
Alec Lord about 1 year ago in AVEVA™ PI System Access (PSA) / PI Web API 1 Planned

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold over 1 year ago in Edge Data Store / Ingress 0 Planned

Support of complex streams with PI Adapter for RDBMS with free attribute selection

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 2 Planned

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 1 year ago in PI Interfaces / PI Interface for OPC DA 1 Planned

Failover support for Adapter for DNP3

This is a new idea for the failover functionality specific to the Adapter for DNP3. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the adapter...
Jiyeon Hwang almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 Planned

Failover support for Adapter for Modbus TCP

This is a new idea for the failover functionality specific to the Adapter for Modbus TCP. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the a...
Jiyeon Hwang almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 1 Planned

Include the 'close=true' URL parameter when data is flushed

Using PI Integrator for Business Analytics to send data to ADLS gen.2 target, then Databricks as a downstream application, though this could apply to any downstream application that relies on Azure Blob Storage events to discover new files. One of...
Guest almost 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 Planned

Avoid necessary registry correction after Click To Run Office update

At our company the unit responsible for deploying software knows about the article KB01529 (Errors with PI DataLink when updating or upgrading Click To Run Office). But they state: According to OSIsofts problem with PI and Office 365 click to run...
Guest about 2 years ago in AVEVA™ PI DataLink™ / Installation & Upgrading 3 Planned

Add more info in NOC cases email subject

It would be better if NOC email cases had the case number as well as the status (Resolved, close or similar) on the email subject
asanzacedo over 2 years ago in Customer Portal & PI Square / General 3 Planned